exposed terminals and wiring on the back. Also, YOKOGAWA Electric Corporation assumes no liability for the customer's, failure to comply with these requirements. the protection provided by this instrument may be impaired. The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. Download digitalview ALR-1400 Instructions manual . 1. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. The Yokogawa TC10-L limit controller is an FM-approved limit controller that can be configured either as a high limit or as a low limit controller by a user. Main Features Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals) 3 Dynamic Colors Led Display Universal input: (TC, mV, V, mA, Pt100-Pt1000) 4 Set Points and alarm functions Serial communication : RS-485 Modbus PID control, ON/OFF, Auto-tuning When a shielded cable is used, it should be connected at one point only. Use a tester or similar device to ensure. Allows to increase the value of the selected parameter. Notes: 1. Model TC10 Temperature Controller, Quick Guide, Model TC10 Temperature Controller, Engineering Manual, Model TC10 Temperature Controller, Serial communication protocol Modbus for TC10, New Legislative Framework (NLF) Conforming Products, List of RoHS (2011/65/EU) Directive Compliant Products (6-substances RoHS compliant products), Replacement Guide for TC10 Temperature Controller, The EU Declaration of Conformity TC10 *Log-in Required. Copyright 1994-2023 Yokogawa Electric Corporation, {{ baseCtrl.fullNavList[baseCtrl.fullNavList[baseCtrl.currentMenuDepth].parent].name }}, {{ baseCtrl.fullNavList[baseCtrl.currentMenuDepth].name }}, Special Solutions of OpreX Transformation, Visual MESA Supply Chain Scheduling (VM-SCS), Visual MESA Production Accounting (VM-PA), Cloud Inventory Management Solutions (Web*VMI), Platform for Advanced Control and Estimation (Advanced Process Control), OpreX Laboratory Information Management System, Remote Plant Performance Operation and Remote Consulting (KBC Co-Pilot Program), Predictive Maintenance of Pump Cavitation, Advanced Analytical Instrument Management System (AMADAS), FluidCom Chemical Injection Flow Controller, Real-time Plant Data Sharing Service (Web*Technician), Digital Plant Operation Intelligence (DPI) Quality Stabilization System, OpreX Data Model Broker / Design Data Validation, OpreX Customer Service Management Software, OpreX IT/OT Security Operations Center (SOC), Plant Information Management System (Exaquantum), Alarm Reporting and Analytics (Exaquantum/ARA), Integrated Production Information (Exaquantum/mPower), Power Performance Calculations (Exaquantum/PPC), Safety Function Monitoring (Exaquantum/SFM), Operator Trending Module (Exaquantum/OTM), Remote Data Synchronization (Exaquantum/RDS), Synchronous OPC DA Manager (Exaquantum/SDM), Manufacturing Data Exchange (Exaquantum/MDX), Public announcement of Yokogawas products, Single-Cell Analysis Solution Single Cellome, Distributed Temperature Sensor - Fire Detection/Fire Prevention -, Industry and Interface Libraries (Applications and Interfaces), Advanced Control Bioreactor System BR1000, ALH for FlowCam: Automated Liquid Handling, Yokogawa announcement to Windows XP users regarding Systems products, A Business Value Decision ofImpact and Significance, Yokogawa Cloud IT/OT Connectors & Integrations, TC10-L Temperature Controller Limit Control Type Engineering Manual, TC10-L Temperature Controller Limit Control Type Serial communicaiton protocol, TC10-L Temperature Controller (Limit Control Type), Model TC10-L Temperature Controller (Limit Control Type), Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), Limit control function (High limit / Low limit), IP65 front panel (when the optional panel gasket is mounted)(optional). Temperature drift: It is part of the global accuracy; Operating temperature: 0 to 50C (32 to 122F); Storage temperature: -20 to +70C (-4 to +158F); Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. 1. Select a mounting location having the following characteristics: 2. (100 to 240 VAC), Insulation voltage: 3000 V AC for 1 minute between primary and secondary terminals, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Serial Communication (optional): RS-485 MODBUS. Use a tester or similar device to ensure. Available: When a linear input is selected by [1] SenS. equipment and devices that ensure personnel safety. 1. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. all phases of operation, service and repair of this instrument. Can I hide the SP display? Installation altitude: less than 2000 m; The instrument can be mounted on panel with a maximum, When the maximum front protection (IP65) is desired, the optional, - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. A ladder sequence function is included as standard. fail to observe these instructions when operating the product. 4. If this instrument is used in a manner not specified in this manual. TC10. Pt 1000 calibration: According to EN 60751/A2. The instrument have one complete parameter set. Features 3 Dynamic Colors Led Display Compact size: 48 x 48 mm (1/16 DIN), depth 48 mm equipment and devices that ensure personnel safety. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. - This product is intended to be handled by skilled/trained person-, - This instrument is for Measurement Category No. I'm sending the temperature via PV transmission on TC10. 16 AWG or larger wires rated for at last 75C. 3. All information about. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features The UT35A/UT32A also support open networks such as Ethernet communication. With thermocouple K input, can I display digits after the decimal point for the temperature? Related Manuals for YOKOGAWA TC10-L . user must refer to the Engineering manual for special instructions. Yokogawa Electric Corporation - TC10 - ENGINEERING MANUAL - PAG. The UT52A/MDL supports 920 MHz band wireless communication. - Wiring should be installed to conform to NEC (National Electrical, Code: ANSI/NFPA-70) or the wiring construction standards in. Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. Input impedance:> 1 M. of use, service life and misuse are not covered by this warranty. When installing the TC10, what is the depth in millimeters from the surface of the panel? IP65 Certification when the optional panel gasket is mounted. Compact size: 48 x 48 mm (1/16 DIN), depth of 48 mm + 14 mm (terminals), Universal input: (TC, mV, V, mA, Pt100-Pt1000), IP65 front panel (when the optional panel gasket is mounted)(optional), Power consumption: 4.5 VA max. and access the next parameter within the same group. - For control relay output, alarm relay output, and power terminal. The following, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. condensation); 5.The ambient temperature is in accordance with the operative temperature (0 to 50C); 6.The relative humidity is in accordance with the instrument specications (20 to 90%); The instrument can be mounted on panel with a maximum thickness of 8 mm. - Modification of the product is strictly prohibited. Model: TC10-L Quick Guide . The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. Is there a controller to which I can connect a 2-wire Pt1000 sensor? Cold junction accuracy: 0.04C/C after a warm-up of 20 minutes. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. facilities, aviation facilities, and medical equipment. These meters commonly measure voltage, resistance, continuity, capacitance, and more. voltage contact between terminals 4 and 16; - 0 to 12 V SSR Drive Output (OP4) connecting, - 12 Vdc (20 mA) transmitter power supply, connecting the 2 wire transmitter between, terminals 4 and 1; for 3 wire transmitter connect, terminal 4 to transmitter power supply input and. Does the TC10 come with a terminal cover? )The state of output relay is energized (closed) and the output (OUT) display lamp turns off if the PV does not exceed SP at power-on. -For supply connections use No. The polarity of the power supply has no importance; The power supply input is NOT fuse protected. 2.The cable length must not exceed 1.5 km at 9600 baud. Note: The complete list of the default parameters is available in Appendix A. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration.